Engineered solution
Industrial mist cooling and humidification
High-pressure mist systems create fine water droplets that evaporate in air, lowering air temperature and raising humidity. They are used to cool work areas and outdoor spaces and to maintain humidity in textile, cultivation and storage environments.
How mist cooling and humidification work
A high-pressure pump drives filtered water through stainless-steel or plastic tubing to nozzles with very small orifices. The water leaves as a fine mist with a large surface area, so it evaporates quickly. Changing water from liquid to vapour absorbs heat from the surrounding air, which lowers the dry-bulb temperature, and the vapour raises relative humidity. The lower limit of temperature is set by the wet-bulb temperature of the air, so the effect is strongest in dry conditions. Whether the aim is cooling or humidification, the principle is the same; what changes is the control target, the number and placement of nozzles and how the system is switched by temperature or humidity sensors.
Where it fits
Mist cooling is applied in hot production halls, workshops, warehouses, loading bays, outdoor seating and livestock housing, and for pre-cooling air at condenser inlets. Humidification is used in textile spinning and weaving, where low humidity can affect yarn behaviour and static, in greenhouses and mushroom cultivation, and in storage of goods affected by dry air. In spaces that are already humid or poorly ventilated, evaporation slows and wetting becomes a risk, so ventilation and control strategy are part of the design, not an afterthought.
Design elements
Typical elements include a pump set, pre-filtration and, where water quality requires it, softening or reverse-osmosis treatment, high-pressure lines and fittings, nozzles with anti-drip valves, zone valves and a controller linked to temperature and humidity sensors. Nozzle spacing and height are set from the space dimensions and airflow so that droplets evaporate before reaching surfaces. Drainage of lines, access for nozzle cleaning and integration with fans or ventilation also need to be planned.
When this approach fits
- Hot working areas where conventional air-conditioning is impractical
- Textile or cultivation areas that need humidity held within a range
- Outdoor or semi-open areas that need local cooling
- Livestock or poultry housing under heat stress
- Condenser or equipment inlet air that would benefit from pre-cooling
Design constraints to confirm
- What are the typical temperature and relative humidity at the site, and what is the target?
- What are the space dimensions, and is it indoor, semi-open or outdoor?
- How is the space ventilated, and how many air changes are there?
- What is the water source and its quality, including hardness and dissolved solids?
- Are there surfaces, products or equipment that must stay dry?
- What power supply and control or BMS interface are available?
Inputs for a site study
Share what you know. Anything you are unsure of can be marked “not known” — our engineers will help confirm it.
- Area
- Indoor outdoor
- Temperature
- Relative humidity (RH)
- Target RH
- Ventilation
- Water quality
- Power
- Control type
Process
How a project typically runs
- Share the application, area and current climate conditions
- We review the information and list unknowns such as ventilation and water quality
- A site study confirms layout, airflow and utility points
- A solution brief and proposal are prepared with stated assumptions
- Supply, installation and commissioning follow as agreed
Cooling, humidity & air
Components and options
Industrial high-pressure mist cooling
Industrial high-pressure mist cooling uses pumps and fine nozzles to release water mist that evaporates into the air, providing evaporative cooling and…
Indoor mist cooling
Indoor mist cooling uses high-pressure pumps and fine anti-drip nozzles to release micron-sized droplets that evaporate quickly, cooling and humidifying indoor spaces…
Outdoor mist cooling
Outdoor mist cooling uses high-pressure misting lines or mist fans to create a cooler, more comfortable microclimate in patios, gardens, resorts, outdoor…
Adiabatic condenser and VRF pre-cooling
Adiabatic condenser and VRF pre-cooling places a line of misting nozzles in front of air-cooled condenser coils, chillers or VRF outdoor units,…
Industrial humidification systems
Industrial humidification systems add moisture to air using high-pressure fogging nozzles, or compressed-air dry fog, to hold humidity at the level a…
Textile spinning and weaving humidification
Textile spinning and weaving humidification uses high-pressure pumps and overhead mist nozzle lines to hold humidity in ginning, pressing, spinning and weaving…
Animal and livestock cooling
Animal and livestock cooling uses evaporative misting and fogging in dairy and cattle sheds, poultry houses, piggeries, stables, kennels and similar buildings…
Ventilation-integrated misting controls
Ventilation-integrated misting controls combine evaporative mist with existing ventilation, using timers, humidity and temperature sensors, zone control and remote monitoring to cool…
Misting pressure pumps and pump sets
Misting pressure pumps and pump sets supply filtered water at the pressure misting, fogging and dust suppression nozzles need, from low-pressure monoblock…
Mist nozzles and anti-drip assemblies
Mist nozzles and anti-drip assemblies are the fine-orifice nozzles that atomise water in misting and fogging systems, in brass or stainless steel…
Misting filters and pre-treatment accessories
Misting filters and pre-treatment accessories remove sediment and limit scale in the water supply to misting and fogging systems, protecting pumps and…
Humidity and temperature controllers
Humidity and temperature controllers switch misting and fogging systems on and off automatically from temperature and humidity readings, and can split large…
Related problems and industries
Frequently asked questions
Will a misting system make the floor or products wet?
A correctly designed system aims for droplets to evaporate before they reach surfaces. Wetting usually results from oversized droplets, nozzles placed too low or too close together, poor ventilation, high ambient humidity or dripping nozzles. These factors are considered when designing nozzle spacing, height and controls.
How much cooling can be expected?
The achievable cooling depends on the ambient temperature and humidity, airflow and ventilation in the space. It is limited by the wet-bulb temperature of the air. Site climate data is needed before any expected effect can be estimated for a particular location.
Is water treatment required?
It depends on the water. Hard water or water with high dissolved solids can scale nozzles and leave deposits. Filtration is normally fitted, and softening or reverse osmosis may be recommended after a water analysis.
Not sure this is the right approach?