Adiabatic condenser and VRF pre-cooling

Adiabatic condenser and VRF pre-cooling places a line of misting nozzles in front of air-cooled condenser coils, chillers or VRF outdoor units, so fine water mist evaporates and cools the intake air before it reaches the coil.

Engineered solutionCooling and humidification
Adiabatic misting nozzles pre-cooling air ahead of a condenser

Overview

Air-cooled condensers reject heat to the surrounding air, and their performance falls as ambient temperature rises. An adiabatic pre-cooling kit lowers the temperature of the air entering the coil by evaporating fine mist in the airstream just ahead of it. The nozzles are positioned so droplets evaporate before reaching the fins. A kit typically includes high-pressure pump connections, precision nozzles, tubing and manifolds, filtration and controls, either solenoids and timers or sensors that run the system only when conditions call for it. Kits can be retrofitted to existing air-cooled chillers, condenser banks, refrigeration units and VRF outdoor units. Results depend on ambient temperature and humidity, load and coil condition.

Selecting a pre-cooling kit

Configuration depends on coil size and face area, airflow, the number and arrangement of units, local climate, water quality and treatment, access around the units and how the kit should be switched. Water quality is especially important to avoid deposits on the coil.

Range overview

Types and variants
  • Adiabatic Cooling Kit for Air-Cooled Condensers
  • Air-Conditioning Misting System
  • Adiabatic Mist Cooling for VRF Systems
Pressure / temperature
  • Droplet Size: Down to About 5 µm
Features
  • Precision Misting Nozzles Ahead of the Coil
  • Tubing and Manifolds
  • Filtration
  • Solenoid and Timer or Sensor-Based Run-on-Demand Control
  • Retrofit to Existing Units

Exact specifications depend on the variant, material and size. Confirm ratings and certification against the datasheet or with our engineers before ordering.

Applications

  • Air-Cooled Chillers
  • Condenser Banks
  • HVAC Condenser Pre-Cooling
  • VRF Outdoor Units
  • Refrigeration Units
  • Data Centres

Industries

  • Commercial HVAC
  • Data centres
  • Manufacturing
  • Warehousing

Information that speeds up a quotation

Share what you know. Anything you are unsure of can be marked “not known” — our engineers will help confirm it.

  • Area
  • Dimensions
  • Indoor outdoor
  • Temperature
  • Relative humidity (RH)
  • Target RH
  • Water quality
  • Ventilation
  • Power
  • Maintenance

Need a datasheet?

Add this family to your enquiry list and mention the variant — we will send the relevant technical documents.

Cooling and humidification

Related and alternative families

Engineered solution

Industrial high-pressure mist cooling

Industrial high-pressure mist cooling uses pumps and fine nozzles to release water mist that evaporates into the air, providing evaporative cooling and…

Cooling and humidification
Engineered solution

Indoor mist cooling

Indoor mist cooling uses high-pressure pumps and fine anti-drip nozzles to release micron-sized droplets that evaporate quickly, cooling and humidifying indoor spaces…

Cooling and humidification
Engineered solution

Outdoor mist cooling

Outdoor mist cooling uses high-pressure misting lines or mist fans to create a cooler, more comfortable microclimate in patios, gardens, resorts, outdoor…

Cooling and humidification
Engineered solution

Industrial humidification systems

Industrial humidification systems add moisture to air using high-pressure fogging nozzles, or compressed-air dry fog, to hold humidity at the level a…

Cooling and humidification
Engineered solution

Textile spinning and weaving humidification

Textile spinning and weaving humidification uses high-pressure pumps and overhead mist nozzle lines to hold humidity in ginning, pressing, spinning and weaving…

Cooling and humidification
Engineered solution

Warehouse humidity control

Warehouse humidity control and mist cooling use high-pressure fogging to manage temperature, humidity, dust and odour in storage buildings, with zoned control…

Cooling and humidification

Frequently asked questions

What information is needed to size an adiabatic pre-cooling kit?

Provide the make-up of your units (chiller, condenser or VRF), coil dimensions or face area, airflow if known, the number of units and their layout, site climate, water source and quality, power supply and preferred control method. Photographs of the units and the space around them help plan nozzle and pipework positions.

Will mist damage the condenser coil?

The kit is designed so droplets evaporate before reaching the coil, and water quality and filtration are chosen to limit mineral deposits. Run-on-demand control avoids misting when it is not needed. Coil condition and local water hardness should be reviewed before installation, and we can advise on treatment.

Ready to specify adiabatic condenser and vrf pre-cooling?

Send the details you have — quantities, sizes, drawings or a part number. Unknowns are fine.