Engineering. Products. Connected possibilities.

Technical guide

What information is needed for a mist-cooling quotation?

A mist-cooling quotation is only as good as the information behind it. This guide lists what to send so that a system can be sized sensibly and expectations set honestly.

Last reviewed November 4, 2026

Why the details matter

High-pressure mist systems cool air by evaporating very fine water droplets. How much cooling is possible depends heavily on the air: in dry conditions water evaporates readily, while in humid weather the effect is smaller and over-misting can leave surfaces wet. The space, ventilation and water quality decide how many nozzles are needed, where they go and how they are protected. That is why a responsible supplier asks questions before quoting, and why no temperature drop should be promised without site data.

The application and the space

Say what you want to achieve: comfort cooling for people in a workshop, cooling an outdoor area, humidification for a process, pre-cooling air for equipment, or cooling animals. Give the dimensions of the area, the height at which nozzles could be mounted, and whether it is enclosed, semi-open or fully open. Photos and a sketch or layout drawing help a great deal, especially for mounting points such as beams, walls and fans.

Current and target conditions

Provide the typical temperature and relative humidity in the area during the season you are concerned about, if possible at different times of day. List heat sources such as furnaces, ovens, motors or roof exposure. Describe the condition you would like to reach, accepting that the result will be limited by the incoming air. If you have temperature and humidity readings from a logger, include them.

Ventilation

Evaporative cooling needs air movement. Moist air must be exhausted or it will build up humidity and reduce the effect. Describe existing exhaust and supply fans, open doors and windows, and the direction of air flow. Mist is often integrated with fans to spread and evaporate it before it can settle.

Water, power and drainage

Fine mist nozzles block easily. State the water source (municipal, borewell, tanker or treated), and send a water analysis if available, particularly hardness and dissolved solids. Filtration is always needed and softening or RO may be advisable. Give the pressure and flow of the supply, and whether a storage tank exists. State the power supply available near the pump location, and whether drainage is available for flushing and any run-off.

Controls, sensitivities and maintenance

Say how you would like the system to run: manual, timer, or controlled by humidity and temperature. Flag anything that must not get wet, such as electrical panels, finished goods, paper or electronics. Indicate who will maintain the system and how often nozzles and filters can be inspected. With this information, a proposal can include realistic nozzle layout, pump selection, water treatment and controls.

What a good proposal should include

With these details, a proposal should set out the nozzle layout and quantity, pump and motor selection, water treatment and filtration, control method, pipework and fittings, and the maintenance tasks expected. It should state assumptions about the incoming air and water clearly, so that you can see what the design depends on. If key information is missing, the proposal should say so rather than fill the gap with an assumption that later proves wrong.

General guidance for preparing an enquiry. It is not a substitute for a qualified engineering review of your application.

Checklist for your enquiry

Share what you know. Anything you are unsure of can be marked “not known” — our engineers will help confirm it.

  • Application
  • Area dimensions
  • Mounting height
  • Enclosure type
  • Current temperature
  • Current RH
  • Heat sources
  • Target condition
  • Ventilation
  • Water source
  • Water quality
  • Power supply
  • Drainage
  • Control mode
  • Dry zones
  • Photos or drawings

Have a requirement?

Send what you know and an engineer will help with the rest.

Related products and solutions

Engineered solution

Industrial high-pressure mist cooling

Industrial high-pressure mist cooling uses pumps and fine nozzles to release water mist that evaporates into the air, providing evaporative cooling and…

Cooling and humidification
Engineered solution

Indoor mist cooling

Indoor mist cooling uses high-pressure pumps and fine anti-drip nozzles to release micron-sized droplets that evaporate quickly, cooling and humidifying indoor spaces…

Cooling and humidification
Engineered solution

Outdoor mist cooling

Outdoor mist cooling uses high-pressure misting lines or mist fans to create a cooler, more comfortable microclimate in patios, gardens, resorts, outdoor…

Cooling and humidification
Engineered solution

Industrial humidification systems

Industrial humidification systems add moisture to air using high-pressure fogging nozzles, or compressed-air dry fog, to hold humidity at the level a…

Cooling and humidification
Engineered solution

Ventilation-integrated misting controls

Ventilation-integrated misting controls combine evaporative mist with existing ventilation, using timers, humidity and temperature sensors, zone control and remote monitoring to cool…

Cooling and humidification
Product family

Misting pressure pumps and pump sets

Misting pressure pumps and pump sets supply filtered water at the pressure misting, fogging and dust suppression nozzles need, from low-pressure monoblock…

Misting equipment
Product family

Mist nozzles and anti-drip assemblies

Mist nozzles and anti-drip assemblies are the fine-orifice nozzles that atomise water in misting and fogging systems, in brass or stainless steel…

Misting equipment
Product family

Misting filters and pre-treatment accessories

Misting filters and pre-treatment accessories remove sediment and limit scale in the water supply to misting and fogging systems, protecting pumps and…

Misting equipment
Product family

Humidity and temperature controllers

Humidity and temperature controllers switch misting and fogging systems on and off automatically from temperature and humidity readings, and can split large…

Misting equipment
Engineered solution

Industrial water softening systems

Ion-exchange softening plants and salt-free conditioners that remove or control calcium and magnesium hardness in process water, protecting boilers, cooling towers, process…

Water treatment
Product family

Cartridge filter systems

Cartridge filter housings and filter cartridges that remove fine particles from water and process liquids, used for RO pre-filtration, polishing, process water…

Water treatment components

Frequently asked questions

How much will mist cooling lower the temperature?

It depends mainly on the humidity of the incoming air, ventilation and the heat load in the space. In dry weather the effect is greater; in humid weather it is smaller. Any estimate should be based on your site conditions, and should not be treated as a guarantee.

Do I need water treatment for a misting system?

Filtration is always needed, because fine nozzles block easily. Depending on hardness and dissolved solids, softening or RO may also be advisable to limit scaling on nozzles and white deposits on surfaces. Sending a water analysis helps decide what is needed.