Engineering. Products. Connected possibilities.

Problem: humidity

Low humidity in a textile production area

Low humidity in spinning, weaving and other textile areas can affect fibre behaviour, static and breakage. Restoring control starts with understanding the heat load, ventilation and existing humidification plant before choosing a solution.

Symptoms and likely causes

What you may be seeing

  • Increased yarn breakage and end-down rates
  • Static build-up and fibre fly in dry conditions
  • Humidity that varies across a department or through the day
  • Existing humidification plant not holding the set point
  • Blocked nozzles or scale from untreated water
  • Seasonal drops in humidity during dry months

Why humidity matters and why it falls

Natural and many synthetic fibres absorb moisture, and their strength, flexibility and electrical behaviour change with relative humidity. When air is too dry, fibres become brittle, static builds up, fly and lint increase, and yarn breakages and quality variation can rise. Humidity drops when outside air is dry, when machine heat warms the room air and lowers its relative humidity, when ventilation brings in dry air, or when existing humidification plant has blocked nozzles, worn pumps, failed sensors or controls that no longer hold the set point. Different process stages typically need different humidity conditions, so the target should be defined per area.

Options to consider

Where a central humidification plant exists, servicing, cleaning, spares and control upgrades may restore performance. Where coverage is insufficient or there is no plant, high-pressure mist humidification can be applied in the department, with nozzles arranged to distribute moisture evenly and controlled from humidity sensors. Air washer and ducted systems are another established approach. In all cases, water quality is important to prevent nozzle blockage and deposits, and ventilation and heat load determine how much moisture must be added.

Questions that decide the answer

  • What relative humidity and temperature does each process stage need?
  • What are the current conditions, measured across the area and over time?
  • What are the room dimensions, machine heat load and ventilation?
  • Is there an existing humidification plant, and what condition is it in?
  • What is the water source and quality?
  • How should the system be controlled and monitored?
This page explains options; it is not a design or a performance guarantee. Suitability depends on site conditions reviewed by an engineer.

Related products and services

Engineered solution

Industrial humidification systems

Industrial humidification systems add moisture to air using high-pressure fogging nozzles, or compressed-air dry fog, to hold humidity at the level a…

Cooling and humidification
Engineered solution

Textile spinning and weaving humidification

Textile spinning and weaving humidification uses high-pressure pumps and overhead mist nozzle lines to hold humidity in ginning, pressing, spinning and weaving…

Cooling and humidification
Product family

Misting pressure pumps and pump sets

Misting pressure pumps and pump sets supply filtered water at the pressure misting, fogging and dust suppression nozzles need, from low-pressure monoblock…

Misting equipment
Product family

Mist nozzles and anti-drip assemblies

Mist nozzles and anti-drip assemblies are the fine-orifice nozzles that atomise water in misting and fogging systems, in brass or stainless steel…

Misting equipment
Product family

Misting filters and pre-treatment accessories

Misting filters and pre-treatment accessories remove sediment and limit scale in the water supply to misting and fogging systems, protecting pumps and…

Misting equipment
Product family

Humidity and temperature controllers

Humidity and temperature controllers switch misting and fogging systems on and off automatically from temperature and humidity readings, and can split large…

Misting equipment
Service

Humidifier commissioning

Humidifier commissioning brings a newly installed humidification system into service through pre-commissioning planning, on-site verification of connections and positioning, and calibration of…

Air-system support
Service

Humidifier servicing and maintenance

Humidifier servicing and maintenance keeps humidification systems reliable and hygienic through planned maintenance visits, routine cleaning and descaling, and reactive call-outs for…

Air-system support
Service

Humidifier spare-parts support

Humidifier spare-parts support supplies replacement wicks, filters, reservoirs, fans, motors, control panels, switches, seals and gaskets to keep existing humidifiers running, with…

Air-system support
Engineered solution

Industrial reverse-osmosis water plants

Skid-mounted reverse-osmosis plants that reduce dissolved salts in raw or pre-treated water to produce process water for boiler feed, pharmaceutical formulation, food…

Water treatment

Frequently asked questions

Can an existing humidification plant be improved rather than replaced?

Often servicing, replacement of worn parts, cleaning of nozzles and upgrading of sensors and controls can improve an existing plant. An inspection of its condition and a review of current versus required conditions help decide.

Why does humidity fall when machines are running?

Machines release heat that warms the room air. Warmer air can hold more moisture, so its relative humidity falls even though the amount of water vapour has not changed. Humidification must therefore account for the heat load.

Is water treatment needed for humidification?

Fine mist nozzles are sensitive to hardness and suspended solids. Depending on the water analysis, filtration, softening or reverse osmosis may be recommended to reduce blockage and deposits.

Describe the problem. We’ll help frame the solution.

Share a part number, a drawing or simply the problem. Unknowns are fine — an engineer will review your enquiry.