Water treatment
Water filtration plants
Engineered water filtration and treatment plants that take raw water from borewells, rivers, lakes or recycled sources through clarification, filtration and disinfection to meet drinking, process or discharge requirements.

Overview
A water filtration plant is assembled from treatment stages chosen for the raw water: screening, coagulation and flocculation, settling in a clarifier, media filtration through sand, carbon or iron-removal media, fine cartridge or membrane filtration, and disinfection by chlorine, UV or ozone. Chemical dosing, pumps, valves and storage complete the system. Smaller duties can be delivered as plug-and-play skids, while larger plants are engineered for the site.
Project delivery typically runs from a water audit and process design (P&ID, HAZOP review and bill of materials) through fabrication, installation and commissioning, with optional remote monitoring and annual maintenance.
Selecting the right filtration plant
Selection depends on what is in the raw water (turbidity, iron, organics, hardness, dissolved solids), the required output quality and flow, and whether the treated water is for drinking, process use or discharge. Seasonal variation in source quality, space, sludge and backwash disposal, and operator skill levels also shape the process train.
Range overview
- Types and variants
- Plug-and-Play Filtration Skid
- Industrial Water Treatment Plant
- Municipal Water Treatment Plant
- Portable Treatment Unit
- Flocculation and Clarification System
- DM Plant
- Zero Liquid Discharge Train
- Materials and grades
- Multi-Grade Sand
- Activated Carbon
- Iron-Removal Media
- Micron Cartridges
- Size range
- 10 m³/h Compact Skid (Example)
- 500 m³/day ZLD Train (Example)
- Pressure / temperature
- Flocculation Detention 20–45 min
- Velocity Gradient 20–80 s⁻¹
- Rapid Mix 1–3 min
- Standards referenced
- IS 10500
- Features
- Water Audit
- P&ID and HAZOP-Based Design
- Chemical Dosing
- Clarifiers
- Chlorine, UV or Ozone Disinfection
- Remote Monitoring Option
- Annual Maintenance Contract Option
Exact specifications depend on the variant, material and size. Confirm ratings and certification against the datasheet or with our engineers before ordering.
Applications
- Drinking Water
- Industrial Process Water
- Equipment Scale and Corrosion Protection
- Pre-Treatment Before Reuse or Discharge
- Irrigation Water
Industries
- Automotive
- Food and beverage
- Dairy
- Paper and pulp
- Oil and gas
- Leather and textiles
- Glass and ceramics
- Chemical
- Pharmaceutical
- Municipal
Information that speeds up a quotation
Share what you know. Anything you are unsure of can be marked “not known” — our engineers will help confirm it.
- Feed source
- Flow
- Inlet analysis
- Outlet target
- Recovery
- Site
- Power
- Disposal
- OPEX
Need a datasheet?
Add this family to your enquiry list and mention the variant — we will send the relevant technical documents.
Water treatment
Related and alternative families
Industrial reverse-osmosis water plants
Skid-mounted reverse-osmosis plants that reduce dissolved salts in raw or pre-treated water to produce process water for boiler feed, pharmaceutical formulation, food…
Commercial reverse-osmosis plants
Compact reverse-osmosis plants for offices, schools, hospitals, hotels, restaurants, apartment blocks and packaged drinking water units, sized for commercial demand where a…
Industrial water softening systems
Ion-exchange softening plants and salt-free conditioners that remove or control calcium and magnesium hardness in process water, protecting boilers, cooling towers, process…
Commercial water softening systems
Water softeners and conditioners for hotels, hospitals, apartment blocks, institutions, salons and malls, used to limit limescale in pipework, water heaters, laundry…
Sand and multimedia filtration systems
Pressure sand and multimedia filters that remove suspended solids, silt and turbidity from raw water, used as RO and softener pre-treatment and…
Activated carbon filtration systems
Activated carbon filters that adsorb chlorine, odour, colour and organic compounds from water, commonly installed ahead of RO membranes and in process…
Related solutions and guides
Frequently asked questions
What should I send for a filtration plant enquiry?
Provide the water source, a recent laboratory analysis (turbidity, TDS, hardness, iron, organics and microbiology where relevant), the required flow and hours of operation, and what the treated water will be used for. Note any discharge rules for backwash or sludge, the available space and whether existing tanks or pumps are to be reused.
What documents can be requested during design?
You can request a process flow diagram, P&ID, equipment list or bill of materials, layout drawings and the basis of design showing the assumed feed and outlet quality. For larger projects a HAZOP review may also be carried out. Ask for the documents you need at enquiry stage so they are included in the scope.
Ready to specify water filtration plants?
Send the details you have — quantities, sizes, drawings or a part number. Unknowns are fine.