Iron and manganese removal plants that oxidise dissolved metals and filter them out on a catalytic media bed, protecting RO membranes, softeners, pipework and fixtures from staining and fouling.

Engineered solutionWater treatment

Overview

Dissolved iron and manganese, common in borewell water, oxidise on contact with air or oxidants and form particles that stain and foul equipment. An iron removal plant oxidises the metals and passes the water through a catalytic filter medium, such as manganese-dioxide-coated sand, which holds the precipitate until it is backwashed out. Backwash can be triggered by sensors, and a polishing stage can be added where a lower outlet level is needed.

Systems are modular, using FRP or epoxy-lined mild-steel vessels with food-grade internals, single or as duplex skids, with a PLC panel and optional SCADA link.

Selecting an iron removal filter

Key inputs are inlet iron and manganese levels, pH, dissolved oxygen, hydrogen sulphide and organic content, along with flow rate. These determine the oxidation method, media type and contact time. Pilot testing on the actual water is useful where chemistry is unusual. Backwash water availability and disposal should be planned from the start.

Range overview

Types and variants
  • IRF-05 Module
  • IRF-20 Module
  • IRF-50 Module
  • Duplex Skid
  • Polishing Stage Option
Materials and grades
  • FRP Vessels
  • Epoxy-Lined Mild Steel Vessels
  • Manganese Dioxide-Coated Sand
  • Catalytic Filter Media
  • Food-Grade Internals
Size range
  • 1–100 m³/h per Module
  • IRF-05: 5 m³/h, 120 L Bed, 0.6 × 1.4 m
  • IRF-20: 20 m³/h, 450 L Bed, 1.0 × 2.2 m
  • IRF-50: 50 m³/h, 1,250 L Bed, 1.8 × 3.4 m
Pressure / temperature
  • Working Pressure 4 kg/cm²
  • Inlet Iron up to 10 / 15 / 30 ppm (IRF-05 / IRF-20 / IRF-50)
Features
  • Oxidation Plus Catalytic Media Filtration
  • Sensor-Triggered Backwash
  • PLC Panel With Optional SCADA
  • Quick-Change Under-Drain Strainers
  • Pilot Testing

Exact specifications depend on the variant, material and size. Confirm ratings and certification against the datasheet or with our engineers before ordering.

Applications

  • Iron and Manganese Removal
  • RO Pre-Treatment
  • Softener Protection
  • Borewell Water Treatment

Industries

  • Manufacturing
  • Hospitality
  • Municipal
  • Food processing

Information that speeds up a quotation

Share what you know. Anything you are unsure of can be marked “not known” — our engineers will help confirm it.

  • Feed source
  • Flow
  • Inlet analysis
  • Outlet target
  • Recovery
  • Site
  • Power
  • Disposal
  • OPEX

Need a datasheet?

Add this family to your enquiry list and mention the variant — we will send the relevant technical documents.

Water treatment

Related and alternative families

Engineered solution

Industrial reverse-osmosis water plants

Skid-mounted reverse-osmosis plants that reduce dissolved salts in raw or pre-treated water to produce process water for boiler feed, pharmaceutical formulation, food…

Water treatment
Engineered solution

Commercial reverse-osmosis plants

Compact reverse-osmosis plants for offices, schools, hospitals, hotels, restaurants, apartment blocks and packaged drinking water units, sized for commercial demand where a…

Water treatment
Engineered solution

Industrial water softening systems

Ion-exchange softening plants and salt-free conditioners that remove or control calcium and magnesium hardness in process water, protecting boilers, cooling towers, process…

Water treatment
Engineered solution

Commercial water softening systems

Water softeners and conditioners for hotels, hospitals, apartment blocks, institutions, salons and malls, used to limit limescale in pipework, water heaters, laundry…

Water treatment
Engineered solution

Water filtration plants

Engineered water filtration and treatment plants that take raw water from borewells, rivers, lakes or recycled sources through clarification, filtration and disinfection…

Water treatment
Engineered solution

Sand and multimedia filtration systems

Pressure sand and multimedia filters that remove suspended solids, silt and turbidity from raw water, used as RO and softener pre-treatment and…

Water treatment

Frequently asked questions

What water tests are needed before specifying an iron removal plant?

A useful analysis includes total and dissolved iron, manganese, pH, dissolved oxygen, hydrogen sulphide, hardness and organic content or colour. These values decide whether air or chemical oxidation is needed and which filter medium will work. Where results are borderline, a pilot test on site water gives better confidence before the full plant is sized.

Can an iron removal filter feed an RO plant directly?

It is commonly installed ahead of RO and softeners because iron and manganese foul membranes and resin. Depending on the outlet level achieved, a cartridge or polishing stage may follow before the RO. Share the RO feed limits from the membrane design so the iron removal stage can be sized to meet them.

Ready to specify iron removal filtration?