Flow switches detect whether flow in a pipe is present, absent or past a set point and change a contact to trigger an alarm, interlock or pump protection. Sight and rotating-wheel flow indicators give a visual check of flow without power.

Product familyFlow measurement

Overview

A flow switch is a binary device: rather than measuring flow continuously, it changes state when flow rises above or falls below an adjustable set point. Common sensing methods include a paddle or vane moved by the flow, a piston or shuttle, and thermal sensors that detect the cooling effect of moving fluid. Typical uses are pump dry-run protection, cooling-water monitoring and low-flow alarms. Selection depends on the fluid, line size, set-point range and the electrical rating of the contact.

Visual flow indicators

Where an operator only needs to see that fluid is moving, a sight flow indicator is a simple option. Full-view, sight-glass, side, right-angle, double-window and rotating-wheel designs let operators observe flow, direction and fluid condition through a glass window without interrupting the process; rotating-wheel types need no power supply. Bodies are made in carbon or mild steel, stainless steel and plastics, with flanged, threaded, socket-weld, clamp or union ends.

Selecting the right flow switch or indicator

For a switch, confirm the fluid, pipe size, normal and minimum flow, the set point at which the contact must change, process pressure and temperature, and the contact type and electrical supply. For an indicator, the window design, body and glass material, end connection and the line's pressure and temperature decide the choice, and each should be checked against actual process conditions.

Range overview

Types and variants
  • Full View Flow Indicators
  • Sight Glass Flow Indicators
  • Side Flow Indicators
  • Right Angle Flow Indicators
  • Rotating Wheel Flow Indicators
  • Dual Sight Flow Indicators
  • Double Window Flow Indicators
  • Wheel Flow Strainers
Materials and grades
  • Carbon Steel
  • Mild Steel (Zinc Plated)
  • SS304
  • SS316
  • Polypropylene
  • PVC
  • Borosilicate Glass
  • PTFE or Neoprene Packing
Size range
  • 1/4 Inch to 16 Inch (Sight Flow Indicators)
  • 1/2 Inch to 2 Inch (Wheel Type)
  • 15 NB to 500 NB (Right Angle)
  • 25 NB to 600 NB (Double Window)
Connections and interfaces
  • Flanged
  • Threaded
  • Sanitary Clamp (TC)
  • Socket Weld
  • Union
Standards referenced
  • ASME/ANSI B16.5 Class 150 Flange Drilling
  • BS 10 Table D, E, F Flange Drilling
Features
  • No Power Supply Needed (Wheel Type)
  • Body Material Chosen to Suit the Fluid

Exact specifications depend on the variant, material and size. Confirm ratings and certification against the datasheet or with our engineers before ordering.

Applications

  • Visual Monitoring of Flow in Pipelines
  • Laboratories and Research Facilities

Industries

  • Oil and gas
  • Refining
  • Chemical
  • Pharmaceutical
  • Food and beverage
  • Power generation
  • Cement
  • Steel
  • Paper
  • Sugar

Information that speeds up a quotation

Share what you know. Anything you are unsure of can be marked “not known” — our engineers will help confirm it.

  • Fluid
  • Flow min
  • Flow max
  • Size
  • Accuracy
  • Pressure
  • Temperature
  • Signal
  • Power
  • Certification

Need a datasheet?

Add this family to your enquiry list and mention the variant — we will send the relevant technical documents.

Flow measurement

Related and alternative families

Product family

Electromagnetic flow meters

Electromagnetic flow meters measure the volumetric flow of electrically conductive liquids in closed pipes, with no moving parts in the flow path.…

Flow measurement
Product family

Ultrasonic flow meters

Ultrasonic flow meters measure liquid flow without contact, using timed signal pulses. For open channels and streams, a sensor above the surface…

Flow measurement
Product family

Turbine flow meters

Turbine flow meters measure the volumetric flow of clean, low-viscosity liquids and gases using a free-spinning rotor whose speed is proportional to…

Flow measurement
Product family

Coriolis flow meters

Coriolis flow meters measure mass flow directly by sensing the twist induced in vibrating measuring tubes as fluid passes through them. Many…

Flow measurement
Product family

Vortex flow meters

Vortex flow meters measure the volumetric flow of liquids, gases and steam by counting the vortices shed from a bluff body placed…

Flow measurement
Product family

Differential-pressure flow sensors

Differential-pressure flow sensors infer flow from the pressure drop across a primary element such as an orifice plate, venturi or pitot tube.…

Flow measurement

Frequently asked questions

What information do you need to quote a flow switch or flow indicator?

Send the fluid, pipe size and end connection, normal and minimum flow, operating pressure and temperature, and the body material you prefer. For a switch, add the set point, contact type and electrical supply. For an indicator, say which window style you need and whether a rotating wheel is wanted to make low flows easier to see.

Should I use a flow switch or a sight flow indicator?

Use a flow switch when the plant must react automatically to loss or excess of flow, for example to stop a pump or raise an alarm. Use a sight flow indicator when an operator only needs to confirm by eye that fluid is moving and looks right. Some lines use both: an indicator for local checks and a switch for protection.

Ready to specify flow switches?